Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 333-337, 2020.
Article in Chinese | WPRIM | ID: wpr-868448

ABSTRACT

Objective:To explore the value of low-dose CT in pregnancy with COVID-19.Methods:A retrospective analysis was performed on the clinical characteristics, laboratory tests, and chest CT findings of 12 pregnant women with COVID-19 diagnosed by nucleic acid testing in the Renmin Hospital of Wuhan University from January 20, 2020 to February 16, 2020. Two radiologists blinded to the reconstruction algorithm independently scored subjective image quality on a 5-point Likert scale. Image quality score ≥ 3 was acceptable in clinics. The CT radiation doses were recorded, including CT volume dose index (CTDI vol), dose length product (DLP), and effective radiation dose ( E). Two radiologists observed the distribution, shape, density, and other characteristics of lung lesions, and they also decided whether hilar, mediastinal lymphadenopathy, and pleural changed. Results:A total of 12 pregnant women with COVID-19, 8 had cough, 4 had fever, 2 had chest tightness, and 1 had dyspnea and diarrhea each. The CT image quality score of all patients was 3-4, with an average of 3.46, which fully met the clinical diagnosis requirements. The CTDI vol value was 1.13-4.31 mGy, with an average of 3.02 mGy. The DLP value was 34.48-75.29 mGy·cm, with an average of 55.48 mGy·cm. The Evalue was 0.48-1.05 mSv, with an average of 0.78 mSv. In all cases, chest CT examination showed abnormal manifestations after clinical symptoms, including unilateral lung lesions in 5 cases and bilateral lung lesions in 7 cases, 1 case of ground-glass opacity, 1 case of solidification, 7 cases of ground-glass and consolidation, 1 case of strip opacity, ground-glass, and consolidation and strip cable shadow coexisted in 2 cases. Conclusions:The application of low-dose CT scan in pregnant women with COVID-19 is completely feasible. CT mainly manifested as bilateral lung patchy and flaky ground-glass opacity with consolidation. Active and effective treatment can help recover and improve prognosis.

2.
Chinese Journal of Radiology ; (12): 296-299, 2020.
Article in Chinese | WPRIM | ID: wpr-868283

ABSTRACT

Objective:To summarize the clinical and high resolution CT(HRCT) characteristics of 141 patients with COVID-19.Methods:From January 20 to 28, 2020, 141 COVID-19 patients, 77 males and 64 females, with a median age of 49 (9, 87), were enrolled in the study. The clinical features, laboratory test results and HRCT findings of all patients were analyzed retrospectively.Results:In all of the patients, the decreasing leukocyte countin 38 (26.95%) and lymphocyte ratio in 71 (50.35%), a fever over 37.5 ℃ in 139 (98.58%), coughing in 106 (75.18%), headache in 11 (7.80%), expectoration in 41 (29.08%), chest distress in 93 (65.96%), and diarrhea in 4 (2.84%) were found. The HRCT of all patients were abnormal, including ground glass opacity (GGO) with patchy opacity in 52 (36.88%) mainly distributed along subpleural area, GGO with focal consolidation in 23 (16.31%),small patchy opacity in 27 (19.15%),large patchy consolidation in 20 (14.18%),thickened bronchovascular bundleing and blood vessel crossing the lesion in 48 (34.04%), air bronchus sign in 5 (3.55%), small nodule in 7 (4.96%),fibrous stripes and reticular opacities in 5 (3.55%), bilateral pleural effusion in 7 (4.96%), and mediastinal or bilateral hilar lymphadenopathy in 4 (2.84%).Conclusions:The clinical and HRCT manifestations of COVID-19 are various. Under the specific epidemiological background of COVID-19, chest HRCT scan should be carried out as soon as possible for early warning of this disease.

3.
Chinese Journal of Radiology ; (12): E006-E006, 2020.
Article in Chinese | WPRIM | ID: wpr-811616

ABSTRACT

Objective@#To summarize the clinical characteristics of 141 patients with novel coronavirus pneumonia (NCP) and the imaging characteristics of High Resolution CT(HRCT) in the chest.@*Methods@#From January 20, 2020 to 28, 141 NCP patients, 77 males and 64 females, with a median age of 49 (9,87), were retrospectively analyzed. The clinical features, laboratory examination indexes and HRCT findings of 141 NCP patients were analyzed.@*Results@#In 141 NCP patients, 38 (26.95%) had a decrease in leukocyte count and 71 (50.35%) had a decrease in lymphocyte ratio. Among 141 NCP patients, 139 (98.58%) had fever (over 37.5 ° C), 106 (75.18%) coughed, 11 (7.80%) had headache, 41 (29.08%) coughed up sputum, 93 (65.96%) had chest distress, and 4 (2.84%) had diarrhea. HRCT of 141 NCP patients were abnormal, 52 (36.88%) showed ground glass shadow (GGO) and patchy shadow, mainly subpleural distribution; 23 (16.31%) showed GGO with focal consolidation; 27 (19.15%) had small patchy blur; 20 (14.18%) had large patchy consolidation; 48 (34.04%) had bronchovascular bundle thickening and vascular perforator sign; 5 (3.55%) had Air bronchus sign; small nodule shadow in 7 cases (4.96%); fibrosis, grid shadow or strip shadow in 5 cases (3.55%); bilateral pleural effusion in 7 cases (4.96%); mediastinal or bilateral hilar lymphadenopathy in 4 cases (2.84%).@*Conclusions@#The clinical features and HRCT images of NCP are various. Under the specific epidemiological background of NCP, HRCT scan of chest should be carried out in time to make early warning of disease.

4.
China Medical Equipment ; (12): 31-34, 2017.
Article in Chinese | WPRIM | ID: wpr-510355

ABSTRACT

Objective:To discuss the clinical value of CT-guided interstitial implantation of125I radioactive particle through the percutaneous puncture in the treatment of central-type lung cancer.Methods: 63 patients with the central-type lung cancer treated in Renmin Hospital of Wuhan University from November 2013 to July 2016 were randomly grouped (31 cases in the control group and 32 cases in the observation group). Patients in the control group were given the treatment of bronchial arterial perfusion with the chemotherapeutic drugs; while patients in the observation group were given the CT-guided interstitial implantation of125I radioactive particle through the percutaneous puncture. The clinical therapeutic effect and complications were observed of the two groups and the quality of life scores before and after the treatment were summarized between two groups as well.Results: The overall effective rate of observation group was 84.38% (27/32) that was higher than 61.29%(19/31) of control group, with statistical difference (x2=4.259,P0.05); the quality of life score of observation group after the treatment was 84.57±3.27 that was higher than 70.38±3.20 of control group, with statistical difference (t=17.402,P<0.05).Conclusion: CT-guided interstitial implantation of125I radioactive particle through the percutaneous puncture in the treatment of patients with central-type lung cancer has the significant effect, and it can effectively improve the quality of life for patients and have the high degree of safety.

5.
Journal of Audiology and Speech Pathology ; (6): 571-574, 2017.
Article in Chinese | WPRIM | ID: wpr-668741

ABSTRACT

Objective To investigate the clinical features,etiology,diagnosis and treatment of acute auditory agnosia.Methods We studied the clinical manifestation,diagnosis and treatment of acute auditory agnosia in a patient in our hospital.Results A 28 year oldyoung woman visited our department because she suffered from the tinnitus for 7 days and she could not distinguish the semantics for 1 day.There were no other abnormal symptoms in the central and peripheral nervous system on admission.Audiological testing showed normal,language testing showed that the speech discrimination score was zero.MRI showed extensive damage to temporal lope.MR spectroscopy revealed increased lactate and reduced N-acetyl aspartate.Acute auditory agnosia resulted from mitochondrial myopathy was considered.After symptomatic treatment,the symptoms were significantly improved.Molecular genetics examination showed the A3243G mtDNA mutation,further confirmed the diagnosis of mitochondrial encephalomyopathy with lactic acidosis and stroke like episodes (MELAS) syndrome.Conclusion Acute auditory agnosia and acute tinnitus can be the first symptoms in MELAS,thus,MELAS should be suspected in patients with acute auditory agnosia,acute tinnitus,sudden hearing loss in children and youth.Imaging examination plays an important role in the etiological diagnosis of acute auditory agnosia.

6.
Chinese Journal of Radiological Medicine and Protection ; (12): 486-488, 2010.
Article in Chinese | WPRIM | ID: wpr-387779

ABSTRACT

Objective To assess the effectiveness of Z-axis automatic tube current modulation ( ATCM) technique with respect to dose reduction and image noise in the thyroid regional tissues during neck computed tomography angiography (CTA). Methods A total of 140 patients underwent neck CTA with 64-slice spiral CT, and were randomized into fixed-tube current group and ATCM group. Objective noise, CTDIw, DLP and mA of each group were recorded. Results The image qualities of all the patients were diagnostically acceptable, though the objective noise of neck in the ATCM group was higher than that in the group of fixed-tube current (P< 0.05 ). The radiation doses in the ATCM group [ CTDIw (35.99±1.31 ) mGy, DLP (11 121.39 ±5.51) mGy·cm] were significantly inferior to those in the group of fixed tube current [ CTDIw (43.22±1.42) mGy, DLP (1514.45±5.56) mGy·cm]. Conclusions Compared with fixedtube current technique, ATCM technique could significantly reduce the radiation dose in neck CT with diagnostic acceptability of the image quality.

7.
Journal of Chongqing Medical University ; (12)2007.
Article in Chinese | WPRIM | ID: wpr-578767

ABSTRACT

Objective:To send all kinds of pictures or images to PACS(Picture Archive and Communication System)and unify the formats of those pictures or images to be generally applied in many hospitals nowadays.Methods:Structures of PACS involved imaging device,data gathering working station,server,display working station and network.DICOM gateway was applied to help diagnose correctly from all kinds of pictures or images.Results:Kinds of file formats could be transformed conveniently with DICOM Gateway.The system could also manage and store intelligently those files in a visual and uniform way.Conclusion:Management and share of various files can be realized with DICOM Gateway.

8.
Journal of Medical Postgraduates ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-586585

ABSTRACT

Objective:To evaluate the correlation of orbital computed tomography and incretion in patients with thyroid associated ophthalmopathy- Ⅰ. Methods : Seventy-six orbits of 38 patients with thyroid associated ophthalmopathy were evaluated by CT in respect to the density and the size of extraocular muscles, and 100 normal orbits of 50 healthy person were evaluated with the same indices for comparison. Results:There was significant difference in the density and the size of extraocular muscles between the patients and the healthy adults. The maximal size of extraocular muscles were positive correlation with T3,T4in TAO-Ⅰ, and negative correlation with TSH. Conclusion:The manifestation of orbital CT may be a good index in the following survey of thyroid associated ophthalmopathy-Ⅰ.

SELECTION OF CITATIONS
SEARCH DETAIL